Electrically conductive plastics

Where electrical charges must flow safely and under controlled conditions, the search begins for the appropriate material solution. Electrically conductive plastics reduce electrostatic charges and are therefore suitable for applications where Protection, procedural certainty and reliability count.

Key data in focus

from 1 x 104 Ω

Surface resistance

up to 1 x 1011 Ω

Surface resistance

from 60 °C

Heat resistance

up to 130 °C

Heat resistance

ISO 9001

Made in Austria

Special solution

Material properties

What makes electrically conductive plastics unique

Conductivity is not a side effect – it is precisely adjusted based on the type and amount of filler and reproduced in a process-safe manner.

ESD protection

Controlled discharge of electrostatic charges – protects sensitive electronics and processes from uncontrolled discharges.

Defined resistance range

The surface resistance can be adjusted specifically – from conductive to non-conductive, which can be precisely formulated according to the standard and requirements.

Explosion protection (ATEX)

In zones with ignition hazards, conductive materials are mandatory – they reliably prevent electrostatic sparks and comply with the standards.

Conductivity without metal corrosion

No cracking, no oxidation – conductive plastics maintain their function even in humid or aggressive environments.

Shielding effect (EMV)

Electromagnetic interference is absorbed or reflected – metallic fillers give the plastic a real shielding effect.

Long-term stability

Conductive additives such as carbon black or CNT remain permanently in the material – no coating that wears off or ages.

Product variants

Which electrically conductive plastics are suitable for you?

Not all materials are the same. We think about the application from a practical perspective – and together find the material that really suits the needs.

PP – Polypropylene

The all-rounder among conductive thermoplastics. Lightweight, chemical-resistant and cost-effective – ideal for containers, housings and structural parts with ESD requirements.

PS – Polystyrene

Stiff, dimensionally stable and well-processed. The electrically conductive PS excels where form stability and defined resistance are required – without a large budget.

ABS – Acrylonitrile-Butadiene-Styrene

Conductive ABS is the classic choice for electronic housings and protective covers – tough, scratch-resistant and proven.

POM – Polyoxymethylene

Precision meets function. Conductive POM is the first choice for moving components, sliding applications, and precision parts – wherever abrasion and discharge are a concern at the same time.

PC – Polycarbonate

When it comes to impact resistance and temperature stability – conductive PC provides both, even under demanding conditions.

Special solutions

When standard materials are not enough, we think further. Together, we develop solutions that are tailored exactly to your requirements – from the compound to series production readiness.

Fields of application

Where electrically conductive plastics their strengths play out

Electronics

Enclosures, IC trays, wafer carriers, PCB covers, plug housings, sensor holders

Intralogistics & Transport

Conveyor chains, conveyor technology, ESD load carriers, trays, sliding guides

SMD

SMD reels, mounting carriers, mounting devices, transport reels, cover caps

Explosion protection

Pump housing, valve body, switch housing, mounting elements, cable guides

Specifications

Technical data

Property Value/Range Norm
Thickness range 25–55 MPa —
Hardness 25–55 MPa DIN ISO 868
Toughness 25–55 MPa ISO 527
Operating temperature −40 °C to +120 °C —
Width (roll) up to 1,500 mm —
References

Selected projects with Electrically conductive plastics

Automotive

Paint Protection Film

Aliphatic TPU film, 0.15 mm, self-healing, transparent – for mass production delivery to Tier-1 suppliers

Medical technology

Biocompatible soft film

ISO 10993-tested TPU film, 0.20 mm, for wound dressing – developed in collaboration with the raw material supplier

Railway

UL 94 V-0 cable jacket

Halogen-free, flame-resistant TPU film according to EN 45545 – development project with a European manufacturer

Why Filzwieser for electrically conductive Plastic injection molding?

Electrically conductive compounds They are among the most demanding materials processed in injection molding.
Homogeneous conductivity distribution, tight tolerance limits – the Experience and that Measuring equipment Many processors do not have that capability. We already have.

With years of experience in the processing of conductive compounds – from standard materials filled with carbon black up to CNT-based high-performance materials – we deliver components that function reproducibly. From the first prototype to series production readiness.

Printed plastic foil on an outdoor display with pink text panel and cow head motif, buildings and a bush in the background

What we are distinguishes

Your
contact person

I am happy to meet you:
Hans-Peter Heigl
Hans-Peter Heigl
FAQ & Background information

Frequently asked questions

What is the difference between conductive and non-conductive?

Electrically conductive plastics have a defined surface resistance of 10⁶ to 1010 Ω – they conduct loads in a controlled manner, without conducting completely. Conductive materials are present below, at 10³ to 10⁶ Ω. Which range is appropriate depends on the standard and application – we can help with the classification.

Through conductive fillers like carbon black, carbon fibers or antistatic additives that are mixed into the base polymer. The type and amount of filler determine the resistance range.

Basically yes – PP, PS, ABS, POM and PC are common base materials for conductive compounds. The challenge lies in the balance: Conductive fillers influence mechanical properties such as toughness or elongation. Together, we examine which material offers the best overall solution.

Conductive compounds place particular demands on the tool and process: increased wear, adapted processing temperatures and Defined flow paths for a homogeneous conductivity distribution in the component. Experience in handling these materials is crucial – and that is exactly what we bring.

Nach oben scrollen