Flame-resistant material

Where fire protection and function must come together in a component, the search begins for the appropriate flame-resistant material. Flame-resistant plastics reduce the flammability and delay the possible spread of the fire – wherever safety, compliance with standards and reliability are important.

Key data in focus

by UL 94 HB

Burning behavior

up to UL 94 5VA

Burning behavior

from 550 °C

GWFI (Glow Wire Flammability Index)

up to 960 °C

GWFI (Glow Wire Flammability Index)

ISO 9001

Made in Austria

Special solution

Material properties

What makes flame-retardant plastics unique

Flame retardants are created through coordinated packages of additives and fillers. This allows the defining of combustion classes, drip behavior, and self-extinguishing properties – suitable for standard, installation space, and application environment.

Safety through defined fuel classes.

Whether it is a device, a connector or a housing – through standardized testing procedures (e.g., UL 94, IEC 60695, …), the fire behavior can be evaluated in a reproducible manner. This provides clear planning certainty for designers and customers and significantly simplifies the necessary approval processes.

Mechanics and flame protection in balance.

Flame retardant additives influence toughness, stiffness and heat resistance. The trick lies in the balance: sufficient safety margin in the event of a fire, while at the same time ensuring that the components are manageable and robust.

Ageing resistance

Temperature, humidity, and UV radiation all alter materials – even flame-resistant ones. Stabilization packages and suitable base polymers ensure that components maintain their properties optimally throughout their lifespan.

Temperature resistance

The materials used must withstand continuous operating temperatures and short-term temperature peaks. Heat resistance (HDT/Vicat) and flame resistance work together as a system – ideal for housings, connectors, and electrical components.

Halogen-free

Flame-resistant plastics are available in halogenated and non-halogenated variants. Halogen-free minimizes smoke and corrosion gases; halogen-containing versions often offer very high flame-retardant reserves. We can work together to determine what is best for your application and environment.

Surface quality despite flame retardant additive

Many flame retardants compromise the surface quality – visible grout lines or rough surfaces are typical problems. Materials that, despite the addition of additives, provide a high-quality, sealed surface are a real differentiator – especially in visible housing components.

Product variants

Which flame-resistant plastics are suitable for you?

Not all materials are the same. We think about the application from a practical perspective – and together find the material that really suits the needs.

PP – Polypropylene, flame-retardant

The lightweight all-rounder for many technical applications where cost-effectiveness and fire protection must be combined.

PC – Polycarbonate, flame-retardant

When high impact resistance and temperature resistance are important – even in the event of a fire.

PC/ABS – flame-resistant blends

The classic for device and electronic housing with a visible surface.

PBT – Polybutylene terephthalate, flame-retardant

Proven material for connectors and reel carriers in electrical engineering.

PA – Polyamide (e.g. PA6 / PA66), flame-retardant

For terminals, connectors and functional components where both mechanics and fire safety are important.

Special solutions

When standard materials are not enough, we think further. Together, we develop solutions that are tailored exactly to your requirements – from the compound to series production readiness.

Fields of application

Where flame-resistant plastics their strengths play out

Electronics

Reel carriers, plug housing, switching housing, terminals and mounts in the vicinity of electrical devices

Automotive and traffic technology

Components in the interior, components in control cabinets, mechanical components in door systems with increased fire protection requirements

Equipment and plant technology

Enclosures, control units, cooling systems in energy storage systems

Building technology & infrastructure

Enclosures for fire detectors and sensors, installation components, distribution systems

Why Filzwieser for Flame-resistant materials in plastic injection molding?

Flame-resistant compounds They are among the more demanding materials in injection molding. Additives can be corrosive, the flow properties change, and the process windows are often narrower than for standard plastics. Nevertheless, your component should function reliably, look good, and meet the required Comply with fire safety standards safely.

That's where we come in: with Experience in processing flame-resistant materials and coordinated tool concepts and one View of the overall system – from the material through to the tooling and into series production. This results in components that not only pass the testing but also perform well in your application over the long term.

Printed plastic foil on an outdoor display with pink text panel and cow head motif, buildings and a bush in the background

What we are distinguishes

Your
contact person

I am happy to meet you:
Hans-Peter Heigl
Hans-Peter Heigl
FAQ & Background information

Frequently asked questions

What does „flame-resistant“ mean for plastics?

Flame-resistant plastics are designed so that they difficult to ignite, slower to burn down or after removing the ignition source self-extinguishing. This is evaluated using standardized testing procedures – this allows materials and components to be classified in a comparable manner. The classification you need depends on the standard, the application area, and the component function.

Flame retardants are produced in plastic by special additives or fillers. These can, for example,. promote the formation of an insulating layer that makes inflammation more difficult or the Slow down the burn. In addition to the flame behavior, the type and amount of additives also influence other properties such as toughness or flow behavior – we take these interactions into account when selecting the material.

Tests such as UL 94 or incandescent wire tests evaluate the fire behavior under defined conditions. For example, we examine how quickly a test sample burns up, whether it evaporates or self-extinguishes. These classifications help you meet legal and regulatory requirements and build clear documentation for your products. We support you in combining requirements and material solutions.

Flame-resistant plastics place special requirements on processing and tooling. The additives exert more pressure on the tool and plasticizing unit than other thermoplastics. Tight process windows require stable temperature settings, injection profile and post-pressure to ensure that surface, filling and fire protection requirements are met.

The venting and annealing systems must be designed so that no critical burns occur on the component. Experience in handling these materials helps us to consider these points from the very beginning – that is exactly what we bring.

Nach oben scrollen